Noise stations : 10/10/2026

One card per station, showing the indicators for the selected day in Greek local time. Lden is the weighted indicator of Directive 2002/49/EC; N70 counts how often the level exceeded 70 dB(A). Coverage and the share attributed to flights show how dependable the figures are.
PROD-SV307A-1
no data
No measurements for this day
PROD-SV307A-2
no data
No measurements for this day
PROD-SV307A-3
no data
No measurements for this day
SPM-01 · spm-01
live
Lden
69.0
dB(A)
Lday 61.2 LAeq,24h 61.8
Levening 60.7 Lmax 96.1
Lnight 63.1 L90 32.8
N70
100
all sources: 218
N70 night
10
all sources: 67
N65 day
127
CAA
N60 night
21
CAA
N68 night (AT): 10 / 6 above the Austrian criterion
Non-aircraft noise at this site: 54%
Events: 599 · matched 246 (41%)
Coverage: 99.9% · 24/24 hours
Quantity: LAF
SPM-02 · spm-02
live
Lden
62.8
dB(A)
Lday 55.3 LAeq,24h 56.1
Levening 57.4 Lmax 97.1
Lnight 56.4 L90 30.4
N70
27
all sources: 73
N70 night
4
all sources: 20
N65 day
91
CAA
N60 night
27
CAA
N68 night (AT): 5 / 6
Non-aircraft noise at this site: 63%
Events: 467 · matched 348 (75%)
Coverage: 99.9% · 24/24 hours
Quantity: LAF
SPM-03 · spm-03
live
Lden
68.5
dB(A)
Lday 63.7 LAeq,24h 63.4
Levening 65.5 Lmax 94.1
Lnight 60.8 L90 34.5
N70
142
all sources: 212
N70 night
15
all sources: 34
N65 day
228
CAA
N60 night
30
CAA
N68 night (AT): 17 / 6 above the Austrian criterion
Non-aircraft noise at this site: 33%
Events: 545 · matched 353 (65%)
Coverage: 99.8% · 24/24 hours
Quantity: LAF
TEST-NSRTW-1
no data
No measurements for this day
TEST-NSRTW-2
no data
No measurements for this day
TEST-NSRTW-3
no data
No measurements for this day